Reduce Labour Costs
Reduce field assembly and associated labour.
The Mechanical Room, Simplified.
Introducing Arctic ThermaFrame — a factory-assembled, all-in-one hydronic mechanical system designed to work seamlessly with Arctic Air-to-Water Heat Pumps. ThermaFrame integrates the buffer tank, circulation pumps, backup boiler, one to four hydronic distribution zones, expansion tank, valves, controls and essential mechanical components into one compact assembly.
With SharkBite quick-connect fittings, integrated filling and purging connections, a built-in flow meter, three air bleed valves, and pressure and temperature gauges, ThermaFrame simplifies installation, commissioning and long-term maintenance.

Less
Fewer
FasterFrom 40 Hours to 10 Hours
Why spend days assembling a hydronic mechanical room when you can install a factory-assembled system in a fraction of the time? A conventional system may require approximately 40 hours of on-site mechanical assembly. ThermaFrame is designed to reduce comparable assembly work to approximately 10 hours by providing major mechanical components already installed and interconnected.
| Comparison | Conventional | ThermaFrame |
|---|---|---|
| Estimated mechanical assembly labour | 40 hours | 10 hours |
| Major Components | Field installed | Factory assembled |
| Pumps and valves | Field mounted | Preinstalled |
| Manifolds | Field assembled | Integrated |
| Field Connections | Custom piping | Simplified quick connections |
| Fill and purge equipment | Individually installed | Integrated |
30 labour hours potentially saved per installation. Estimated 75% reduction in on-site mechanical assembly labour.
Note: These figures are planning estimates, not validated installation test results. They exclude other project work and depend on jobsite conditions and system configuration.
ThermaFrame helps HVAC contractors and hydronic installers work more efficiently, estimate confidently and free up time for additional projects.
Reduce field assembly and associated labour.
Increase installation capacity without adding crew members.
Lower labour costs and improve cost predictability.
One coordinated system instead of dozens of parts.
Standardized layouts reduce custom piping work.
Make mechanical scope and estimates more consistent.
Help qualified HVAC contractors approach air-to-water projects.
Repeatable layouts support diagnostics and maintenance.
Factory-Assembled. Professionally Engineered. Ready to Connect

Radiant Floors. Central Forced Air. Fan Coils. One Integrated System.
ThermaFrame supports one to four independently controlled hydronic distribution zones, allowing contractors to combine radiant floor heating, central forced-air heating and cooling through a hydronic air handler, and individual fan coil zones.
| Zone | Distribution | Example Use |
|---|---|---|
| 1 | Radiant floor | Main living area |
| 2 | Radiant floor | Basement or bathrooms |
| 3 | Hydronic air handler | Central forced-air heating and cooling |
| 4 | Hydronic fan coil | Bedroom, office or separate area |
Mixed supply-temperature applications may require mixing arrangements and controls. Cooling circuits require suitable condensation protection; simultaneous heating and cooling is configuration-dependent.
Fill. Purge. Verify. Operate.

Separate service connections simplify filling, flushing, air purging and draining.

Visual verification of circulation supports startup and troubleshooting.

Designated air removal points help clear trapped air.

Built-in gauges allow convenient checks of operating conditions.

Designated circuits and components can be isolated for service.
ThermaFrame consolidates mechanical work into a repeatable factory-assembled package. Contractors can reduce field labour for pump mounting, manifold assembly, valve installation and interconnecting pipework. Integrated piping may reduce extra fittings, brackets, pipe lengths and miscellaneous installation materials. A coordinated package also cuts time spent purchasing, receiving and organizing parts from multiple suppliers.
Actual net savings depend on ThermaFrame package pricing, freight and project conditions.
Heating. Cooling. Backup Heating. Up to Four Distribution Zones. All in One System.
ThermaFrame connects to compatible Arctic Air-to-Water Heat Pumps. In heating mode, the heat pump transfers energy from outdoor air to the hydronic system. The integrated backup boiler can supplement heating when required. Compatible reversible heat pumps can also provide chilled water to properly designed fan coils and hydronic air handlers.

Controlled Cooling. Advanced Heating. Optional Insulation.
Customize your ThermaFrame system with optional upgrades to suit your heating and cooling needs. Available options include the DeltaTherm Mini controller for radiant floor cooling, the ECO-0600 controller for advanced heating control, and a pipe insulation package designed to reduce unwanted heat transfer.

Compact system controller
Supports demand-based radiant floor cooling, using humidity sensor measurements to calculate the dew point.

For heating and cooling applications
Delivering precise temperature management, improved energy efficiency, and reliable system performance.

To cover all green pipes.
For ThermaFrame piping and connections to the heat pump, helping reduce heat transfer during heating and cooling.
| Model | Buffer tank | Distribution Options |
|---|---|---|
| ThermaFrame 22 | 22 gallons | 1-2 configurable zones |
| ThermaFrame 40 | 40 gallons | 1-3 configurable zones |
| ThermaFrame 55 | 55 gallons | 1-4 configurable zones |
Final selection depends on heat pump capacity, minimum water volume, load, required flow, active zones, and hydraulic design. Available model/zone combinations are subject to final product specifications.
ThermaFrame supports a wide range of residential and light-commercial hydronic heating and cooling applications.
Residential hydronic retrofits
Radiant floor heating
Central hydronic forced-air systems
Multi-zone fan coil installations
Combined radiant and forced-air systems
Suitable light-commercial hydronic applications
ThermaFrame pairs with a separately selected compatible Arctic Air-to-Water Heat Pump.
Yes. An integrated electric boiler provides supplemental heating when required.
ThermaFrame is designed to reduce comparable on-site mechanical assembly from approximately 40 hours to 10 hours. Actual labour depends on jobsite conditions and system configuration.
The system supports one to four independently controlled hydronic distribution zones, depending on the configuration.
Yes. It can serve radiant floors, a central hydronic air handler, and individual fan coil zones. Mixed supply temperatures may require additional controls.
Yes. Designated field connections use approved SharkBite push-to-connect fittings for compatible PEX or copper pipe.
Dedicated fill and drain connections, air bleed valves, a flow meter, and built-in gauges simplify commissioning.
Yes. ThermaFrame can be used in suitable residential hydronic retrofits.
Qualified HVAC contractors and hydronic installers can install ThermaFrame. Contact Arctic for installer information.
The Mechanical Room, Simplified.
Why build a mechanical room one component at a time? ThermaFrame combines the essential elements of a modern hydronic heating and cooling system into one integrated, factory-assembled solution. Spend less time assembling mechanical systems and more time completing installations.
SimplifyHave questions about our energy-efficient heating solutions? We're here to help! Whether you need product details, installation support, or assistance with an order, our team is ready to assist you.
Get in touch, no matter where you’re at in your project plans. We’d be so happy to help!