Use our Sizing Tools to find out how much you could save! Visit Sizing Tools
Search
User Account
Cart
Arctic Heat Pumps

THERMAFRAMETM

The Mechanical Room, Simplified.

Introducing Arctic ThermaFrame — a factory-assembled, all-in-one hydronic mechanical system designed to work seamlessly with Arctic Air-to-Water Heat Pumps. ThermaFrame integrates the buffer tank, circulation pumps, backup boiler, one to four hydronic distribution zones, expansion tank, valves, controls and essential mechanical components into one compact assembly.

With SharkBite quick-connect fittings, integrated filling and purging connections, a built-in flow meter, three air bleed valves, and pressure and temperature gauges, ThermaFrame simplifies installation, commissioning and long-term maintenance.

Arctic ThermaFrame hydronic mechanical system
  • LabourLess
    Labour
  • GearsFewer
    Components
  • ToolsFaster
    Installation

Save Up to 75% on Mechanical Assembly Labour

From 40 Hours to 10 Hours

Why spend days assembling a hydronic mechanical room when you can install a factory-assembled system in a fraction of the time? A conventional system may require approximately 40 hours of on-site mechanical assembly. ThermaFrame is designed to reduce comparable assembly work to approximately 10 hours by providing major mechanical components already installed and interconnected.

ComparisonConventionalThermaFrame
Estimated mechanical assembly labour40 hours10 hours
Major ComponentsField installedFactory assembled
Pumps and valvesField mountedPreinstalled
ManifoldsField assembledIntegrated
Field ConnectionsCustom pipingSimplified quick connections
Fill and purge equipmentIndividually installedIntegrated

Clock30 labour hours potentially saved per installation. Estimated 75% reduction in on-site mechanical assembly labour.

Note: These figures are planning estimates, not validated installation test results. They exclude other project work and depend on jobsite conditions and system configuration.

Built for Installers. Designed for Profitability.

ThermaFrame helps HVAC contractors and hydronic installers work more efficiently, estimate confidently and free up time for additional projects.

Benefit 1

Reduce Labour Costs

Reduce field assembly and associated labour.

Benefit 2

Complete More Installations

Increase installation capacity without adding crew members.

Benefit 3

Improve Profit Potential

Lower labour costs and improve cost predictability.

Benefit 4

Simplify Purchasing

One coordinated system instead of dozens of parts.

Benefit 5

Reduce Field-Assembly Risk

Standardized layouts reduce custom piping work.

Benefit 6

Quote With Confidence

Make mechanical scope and estimates more consistent.

Benefit 7

Expand Into Hydronics

Help qualified HVAC contractors approach air-to-water projects.

Benefit 8

Standardize Service

Repeatable layouts support diagnostics and maintenance.

A Complete Hydronic Mechanical System

Factory-Assembled. Professionally Engineered. Ready to Connect

ThermaFrame product diagram with nine numbered components
  1. Insulated buffer tank — thermal storage and stable operation.
  2. Integrated backup electric boiler — supplemental heating when required.
  3. Expansion tank — accommodates thermal expansion in a closed-loop system.
  4. Heat pump circulation pump — maintains heat pump circuit flow
  5. Three air bleed valves — air removal at designated locations.
  6. Pressure and temperature gauges — operating-condition checks.
  7. Integrated flow meter — visual flow verification.
  8. Dual fill service ports — supply and distribution side
  9. One to four distribution pumps — independently controlled hydronic circuits, according to configuration.

Additional Components

  • Supply and return distribution manifolds — organized zone connections.
  • Isolation and check valves — service isolation and proper flow direction.
  • Integrated controls — coordination of heating, cooling, circulation and backup functions.
  • Heavy-duty steel frame — compact, organized equipment support.
  • SharkBite push-to-connect fittings — solder-free connections for approved PEX or copper pipe.

One to Four Independent Distribution Zones

Radiant Floors. Central Forced Air. Fan Coils. One Integrated System.

ThermaFrame supports one to four independently controlled hydronic distribution zones, allowing contractors to combine radiant floor heating, central forced-air heating and cooling through a hydronic air handler, and individual fan coil zones.

ZoneDistributionExample Use
1Radiant floorMain living area
2Radiant floorBasement or bathrooms
3Hydronic air handlerCentral forced-air heating and cooling
4Hydronic fan coilBedroom, office or separate area

Mixed supply-temperature applications may require mixing arrangements and controls. Cooling circuits require suitable condensation protection; simultaneous heating and cooling is configuration-dependent.

SharkBite Quick-Connect
Installation

Connect. Secure. Done. No Soldering Required.

SharkBite Quick-Connect Installation

At designated field connection points, properly prepared compatible PEX or copper pipe can be inserted directly into approved SharkBite push-to-connect fittings. This eliminates soldering and torch work at those connections and can reduce the number of specialized tools required.

  • Shark 1Fast, straightforward pipe connections
  • Shark 2No soldering at approved push-fit connections
  • Shark 3Compatible with approved PEX and copper piping
  • Shark 4Simplified heat pump supply and return connections
  • Shark 5Convenient connections to hydronic distribution circuits
  • Shark 6Watertight seals when installed according to the fitting manufacturer’s instructions

Designed for Easy Commissioning and Maintenance

Fill. Purge. Verify. Operate.

Fills

Dedicated Supply & Distribution Fill/Drain Ports

Separate service connections simplify filling, flushing, air purging and draining.

Meter

Integrated Flow Meter

Visual verification of circulation supports startup and troubleshooting.

Bleed

Three Air Bleed Valves

Designated air removal points help clear trapped air.

Gauge

Pressure & Temperature Gauges

Built-in gauges allow convenient checks of operating conditions.

Isolation

Accessible Isolation Valves

Designated circuits and components can be isolated for service.

Save on Labour, Materials & Installation Time

ThermaFrame consolidates mechanical work into a repeatable factory-assembled package. Contractors can reduce field labour for pump mounting, manifold assembly, valve installation and interconnecting pipework. Integrated piping may reduce extra fittings, brackets, pipe lengths and miscellaneous installation materials. A coordinated package also cuts time spent purchasing, receiving and organizing parts from multiple suppliers.

Contractors

For Contractors

  • More predictable costs
  • Fewer field assembly tasks
  • Greater potential installation capacity
Homeowners

For Homeowners

  • A professionally organized system
  • Potentially lower total installed cost
  • Easier access for future servicing.

Actual net savings depend on ThermaFrame package pricing, freight and project conditions.

Designed for Arctic Air-to-Water Heat Pumps

Heating. Cooling. Backup Heating. Up to Four Distribution Zones. All in One System.

ThermaFrame connects to compatible Arctic Air-to-Water Heat Pumps. In heating mode, the heat pump transfers energy from outdoor air to the hydronic system. The integrated backup boiler can supplement heating when required. Compatible reversible heat pumps can also provide chilled water to properly designed fan coils and hydronic air handlers.

Arctic air-to-water heat pump connected through ThermaFrame to two radiant floor circuits and a hydronic air handler.

Optional ThermaFrame Upgrades

Controlled Cooling. Advanced Heating. Optional Insulation.

Customize your ThermaFrame system with optional upgrades to suit your heating and cooling needs. Available options include the DeltaTherm Mini controller for radiant floor cooling, the ECO-0600 controller for advanced heating control, and a pipe insulation package designed to reduce unwanted heat transfer.

Delta
er>

DELTATHERM® HC
MINI CONTROLLER

Compact system controller

Supports demand-based radiant floor cooling, using humidity sensor measurements to calculate the dew point.

Eco
er>

ECO-0600
CONTROLLER

For heating and cooling applications

Delivering precise temperature management, improved energy efficiency, and reliable system performance.

Insulation
er>

INSULATION
PACKAGE

To cover all green pipes.

For ThermaFrame piping and connections to the heat pump, helping reduce heat transfer during heating and cooling.

ThermaFrame Configurations

ModelBuffer tankDistribution Options
ThermaFrame 2222 gallons1-2 configurable zones
ThermaFrame 4040 gallons1-3 configurable zones
ThermaFrame 5555 gallons1-4 configurable zones

Final selection depends on heat pump capacity, minimum water volume, load, required flow, active zones, and hydraulic design. Available model/zone combinations are subject to final product specifications.

Applications

ThermaFrame supports a wide range of residential and light-commercial hydronic heating and cooling applications.

  • App 1New residential construction
  • App 2Residential hydronic retrofits
  • App 3Radiant floor heating
  • App 4Central hydronic forced-air systems
  • App 5Multi-zone fan coil installations
  • App 6Combined radiant and forced-air systems
  • App 7Suitable light-commercial hydronic applications

View the Arctic ThermaFrame in 360°

Arctic ThermaFrame on a display turntable

ThermaFrame FAQs

Does ThermaFrame include the heat pump?

ThermaFrame pairs with a separately selected compatible Arctic Air-to-Water Heat Pump.

Does it include backup heating?

Yes. An integrated electric boiler provides supplemental heating when required.

How much labour can it save?

ThermaFrame is designed to reduce comparable on-site mechanical assembly from approximately 40 hours to 10 hours. Actual labour depends on jobsite conditions and system configuration.

How many zones?

The system supports one to four independently controlled hydronic distribution zones, depending on the configuration.

Can it combine radiant floors, forced air and fan coils?

Yes. It can serve radiant floors, a central hydronic air handler, and individual fan coil zones. Mixed supply temperatures may require additional controls.

Does it use SharkBite?

Yes. Designated field connections use approved SharkBite push-to-connect fittings for compatible PEX or copper pipe.

Is it easy to commission?

Dedicated fill and drain connections, air bleed valves, a flow meter, and built-in gauges simplify commissioning.

Can it be used in existing homes?

Yes. ThermaFrame can be used in suitable residential hydronic retrofits.

Can HVAC contractors install it?

Qualified HVAC contractors and hydronic installers can install ThermaFrame. Contact Arctic for installer information.

ARCTIC THERMAFRAMETM

The Mechanical Room, Simplified.

Why build a mechanical room one component at a time? ThermaFrame combines the essential elements of a modern hydronic heating and cooling system into one integrated, factory-assembled solution. Spend less time assembling mechanical systems and more time completing installations.

  • Footer 1Save
    Labour
  • Footer 2Simplify
    Installation
  • Footer 3Improve
    Profitability

Connect with an Arctic
Heat Expert

No one knows air to water heat pumps like we do!

Have questions about our energy-efficient heating solutions? We're here to help! Whether you need product details, installation support, or assistance with an order, our team is ready to assist you.

Get in touch, no matter where you’re at in your project plans. We’d be so happy to help!

Arctic Heat pumps Logo

Let Us Help

Our Products

Resources